Panasonic HVAC 12K BTU 4-Way Cassette Ductless Mini Split System - Heat Pump & Air Conditioner

Panasonic HVAC E12RB4U
SKU PAN-E12RB4U
Shop HomElectrical for Cassette Mounted Mini Split Units that are equipped with high efficiency multi-blade fans that generate airflow through the room, and an elegant design.
Panasonic HVAC 12K BTU 4-Way Cassette Ductless Mini Split System - Heat Pump & Air Conditioner

Image may not depict product actual color, inclusions or accessories

Shop HomElectrical for Cassette Mounted Mini Split Units that are equipped with high efficiency multi-blade fans that generate airflow through the room, and an elegant design.

Panasonic 12K BTU, 18 SEER, 4-Way Cassette, Quiet Airflow, Heat Pump Features:

  • 1 Ton Outdoor Condenser (included).
  • Indoor Ductless Wall Mount (Included).
  • LCD display allows the user to control the temperature, louvers (sweep), fan speeds, and timers (included).
  • Optional wired remote control sold separately
  • Ceiling Cassette Grill Cover sold separately
  • Self-Diagnostics automatically ensure problems are discovered early.
  • 5 Fan Speeds and Automatic Fan Operation.
  • ECONAVI sensor detects movement and adjusts louvers for optimal energy saving.
  • Room Freeze Protection to prevent plumbing damage in sub-freezing temperatures.
  • 24 Hour timer lets you create a custom schedule for optimal comfort.
  • Automatic on for heat pump operation in temperatures under 46?.
  • The Dry Mode compressor and fan operation creates a precisely dehumidified environment.
  • Air sweep and dry mode ensure that the entire room is heated or cooled, and excess humidity is removed.
  • Base pan heater in exterior XF models prevents freezing.
  • Automatically changes from heating to cooling and vice versa if the temperature is above or below the set temperature.
  • Automatic restart function after power failure.
  • Low Ambient Heating Model: temperatures range from 5? to -15?.
  • Electrical refrigerant control valve is controlled by pulse type electrical controls and is used to obtain optimum operating efficiency.
  • Low fan speed provides extra quiet operation.
  • Built in 20 Max Amp Drain pump.
  • Optional filter sign provides the opportunity for notification of necessary filter maintenance.
  • Anti-microbial filter prevents growth of mold, mildew, and spores.
  • This anti-rust coasted condenser helps prevent corrosion.
  • Microprocessor controllers automatically adjust fan speed to High, Medium, or Low to maintain an optimal room temperature.
  • Requires 1/4-inch x 3/8-inch refrigerant line set (not included)

Application:

  • This single zone unit allows you to cleanly and quietly heat and cool a large range of rooms in a building. Perfect for light commercial use!.

Panasonic HVAC E12RB4U Description

Panasonic 12K BTU, 18 SEER, 4-Way Cassette, Quiet Airflow, Heat Pump Features:

  • 1 Ton Outdoor Condenser (included).
  • Indoor Ductless Wall Mount (Included).
  • LCD display allows the user to control the temperature, louvers (sweep), fan speeds, and timers (included).
  • Optional wired remote control sold separately
  • Ceiling Cassette Grill Cover sold separately
  • Self-Diagnostics automatically ensure problems are discovered early.
  • 5 Fan Speeds and Automatic Fan Operation.
  • ECONAVI sensor detects movement and adjusts louvers for optimal energy saving.
  • Room Freeze Protection to prevent plumbing damage in sub-freezing temperatures.
  • 24 Hour timer lets you create a custom schedule for optimal comfort.
  • Automatic on for heat pump operation in temperatures under 46?.
  • The Dry Mode compressor and fan operation creates a precisely dehumidified environment.
  • Air sweep and dry mode ensure that the entire room is heated or cooled, and excess humidity is removed.
  • Base pan heater in exterior XF models prevents freezing.
  • Automatically changes from heating to cooling and vice versa if the temperature is above or below the set temperature.
  • Automatic restart function after power failure.
  • Low Ambient Heating Model: temperatures range from 5? to -15?.
  • Electrical refrigerant control valve is controlled by pulse type electrical controls and is used to obtain optimum operating efficiency.
  • Low fan speed provides extra quiet operation.
  • Built in 20 Max Amp Drain pump.
  • Optional filter sign provides the opportunity for notification of necessary filter maintenance.
  • Anti-microbial filter prevents growth of mold, mildew, and spores.
  • This anti-rust coasted condenser helps prevent corrosion.
  • Microprocessor controllers automatically adjust fan speed to High, Medium, or Low to maintain an optimal room temperature.
  • Requires 1/4-inch x 3/8-inch refrigerant line set (not included)

Application:

  • This single zone unit allows you to cleanly and quietly heat and cool a large range of rooms in a building. Perfect for light commercial use!.

This page is for your reference only.

Product Specifications

Part NumberE12RB4U, CS-E12RB4UW, CU-E12RB4U, CZ-BT20U
Air Flow (CFM)390/370
ConfigurationCassette
Cooling Capacity11900 BTU/H
Cooling Power Input1150W
Cooling Running Amps0.25 A
Fan SpeedsHi/Me/Lo & Auto
Fuse/Circuit Breaker Capacity15 A
Heating Capacity13600 BTU/H
Heating Power Input1360W
Heating Running Amps6.9 A
Highest Decibel Rating34 dB-A
HSPF9
Indoor Unit ModelCS-E12RB4U
Max Height Above Outdoor Unit49 Ft
Max Height Below Outdoor Unit49 Ft
Moisture Removal Pints/H4
Outdoor Unit ModelCU-E12RB4U
Power Supply230/208V, 1Ph, 60Hz
RefrigerantR-410A
Refrigerant ControlElectric Expansion Valve
Refrigerant Pipe Connection MethodFlare
Refrigerant Pipe length65 Ft
Sealed BatteryNo
SEER18
Suction Line0.5
Weight86.50-lb
UPC885170312357

Manufacturer Description

Air is returned through the center of the grille, while evenly distributing air through each of the 4 supply air openings. Installation in the center of the room provides for the greatest comfort. However, 1 or 2 supply louvers can be closed for installation near 1 wall to provide 3 or 2 way airflow. Also, by closing off 1 supply louver, you may attach a duct (field supply) to the upper plenum and provide conditioned air to another, separate area.

Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.
Shop HomElectrical for Cassette Mounted Mini Split Units that are equipped with high efficiency multi-blade fans that generate airflow through the room, and an elegant design.
Panasonic HVAC 12K BTU 4-Way Cassette Ductless Mini Split System - Heat Pump & Air Conditioner

This page is for your reference only.

Panasonic HVAC E12RB4U Description

Panasonic 12K BTU, 18 SEER, 4-Way Cassette, Quiet Airflow, Heat Pump Features:

  • 1 Ton Outdoor Condenser (included).
  • Indoor Ductless Wall Mount (Included).
  • LCD display allows the user to control the temperature, louvers (sweep), fan speeds, and timers (included).
  • Optional wired remote control sold separately
  • Ceiling Cassette Grill Cover sold separately
  • Self-Diagnostics automatically ensure problems are discovered early.
  • 5 Fan Speeds and Automatic Fan Operation.
  • ECONAVI sensor detects movement and adjusts louvers for optimal energy saving.
  • Room Freeze Protection to prevent plumbing damage in sub-freezing temperatures.
  • 24 Hour timer lets you create a custom schedule for optimal comfort.
  • Automatic on for heat pump operation in temperatures under 46?.
  • The Dry Mode compressor and fan operation creates a precisely dehumidified environment.
  • Air sweep and dry mode ensure that the entire room is heated or cooled, and excess humidity is removed.
  • Base pan heater in exterior XF models prevents freezing.
  • Automatically changes from heating to cooling and vice versa if the temperature is above or below the set temperature.
  • Automatic restart function after power failure.
  • Low Ambient Heating Model: temperatures range from 5? to -15?.
  • Electrical refrigerant control valve is controlled by pulse type electrical controls and is used to obtain optimum operating efficiency.
  • Low fan speed provides extra quiet operation.
  • Built in 20 Max Amp Drain pump.
  • Optional filter sign provides the opportunity for notification of necessary filter maintenance.
  • Anti-microbial filter prevents growth of mold, mildew, and spores.
  • This anti-rust coasted condenser helps prevent corrosion.
  • Microprocessor controllers automatically adjust fan speed to High, Medium, or Low to maintain an optimal room temperature.
  • Requires 1/4-inch x 3/8-inch refrigerant line set (not included)

Application:

  • This single zone unit allows you to cleanly and quietly heat and cool a large range of rooms in a building. Perfect for light commercial use!.

Product Specifications

Part NumberE12RB4U, CS-E12RB4UW, CU-E12RB4U, CZ-BT20U
Air Flow (CFM)390/370
ConfigurationCassette
Cooling Capacity11900 BTU/H
Cooling Power Input1150W
Cooling Running Amps0.25 A
Fan SpeedsHi/Me/Lo & Auto
Fuse/Circuit Breaker Capacity15 A
Heating Capacity13600 BTU/H
Heating Power Input1360W
Heating Running Amps6.9 A
Highest Decibel Rating34 dB-A
HSPF9
Indoor Unit ModelCS-E12RB4U
Max Height Above Outdoor Unit49 Ft
Max Height Below Outdoor Unit49 Ft
Moisture Removal Pints/H4
Outdoor Unit ModelCU-E12RB4U
Power Supply230/208V, 1Ph, 60Hz
RefrigerantR-410A
Refrigerant ControlElectric Expansion Valve
Refrigerant Pipe Connection MethodFlare
Refrigerant Pipe length65 Ft
Sealed BatteryNo
SEER18
Suction Line0.5
Weight86.50-lb
UPC885170312357

Manufacturer Description

Air is returned through the center of the grille, while evenly distributing air through each of the 4 supply air openings. Installation in the center of the room provides for the greatest comfort. However, 1 or 2 supply louvers can be closed for installation near 1 wall to provide 3 or 2 way airflow. Also, by closing off 1 supply louver, you may attach a duct (field supply) to the upper plenum and provide conditioned air to another, separate area.

Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.

Product Questions & Answers

Customer Reviews

0 out of 5
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Need Assistance?