Hammond 40kVA Tribune Drive Isolation Transformer, Copper, 460V

Hammond DM040JJC
SKU HPS-DM040JJC
Hammond's 40kVA Tribune drive isolation transformer has a NH6 case style with 460 Delta primary volts and 460Y/266 secondary volts. It has a Type 3R enclosure with copper conductors. Browse more transformers at HomElectrical.com today!
Hammond 40kVA Tribune Drive Isolation Transformer, Copper, 460V

Image may not depict product actual color, inclusions or accessories

Hammond's 40kVA Tribune drive isolation transformer has a NH6 case style with 460 Delta primary volts and 460Y/266 secondary volts. It has a Type 3R enclosure with copper conductors. Browse more transformers at HomElectrical.com today!
cUL/UL Listed
CSA US

  • 40kVA; Copper wound.
  • 460 Delta Primary Volts; 460Y/266 Secondary Volts.
  • Designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

cUL/UL Listed
CSA US

Hammond DM040JJC Description

cUL/UL Listed
CSA US

  • 40kVA; Copper wound.
  • 460 Delta Primary Volts; 460Y/266 Secondary Volts.
  • Designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

cUL/UL Listed
CSA US
Free Shipping
$3,543.69Each

Usually Ships 1-2 Months

Product Specifications

Part NumberDM040JJC
CertificatecUL/UL Listed, CSA US
Electrical Phase3 Ph
Inner Package1
MaterialCopper
Maximum Voltage460V
Warranty10 Yr
Product Dimensions28.75-in X 25-in X 23.90-in
Weight380.00-lb
UPC803423003180

Manufacturer Description

DRIVE 3PH 40KVA 460-460 CU
Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.
Hammond's 40kVA Tribune drive isolation transformer has a NH6 case style with 460 Delta primary volts and 460Y/266 secondary volts. It has a Type 3R enclosure with copper conductors. Browse more transformers at HomElectrical.com today!
Hammond 40kVA Tribune Drive Isolation Transformer, Copper, 460V
Free Shipping
$3,543.69Each

Usually Ships 1-2 Months

Hammond DM040JJC Description

cUL/UL Listed
CSA US

  • 40kVA; Copper wound.
  • 460 Delta Primary Volts; 460Y/266 Secondary Volts.
  • Designed to meet the rugged demands of both AC and DC variable speed drives and also provide the required voltage change.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

Product Specifications

Part NumberDM040JJC
CertificatecUL/UL Listed, CSA US
Electrical Phase3 Ph
Inner Package1
MaterialCopper
Maximum Voltage460V
Warranty10 Yr
Product Dimensions28.75-in X 25-in X 23.90-in
Weight380.00-lb
UPC803423003180

Manufacturer Description

DRIVE 3PH 40KVA 460-460 CU
Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.

Product Questions & Answers

Customer Reviews

0 out of 5
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Order With Free Shipping