Hammond 225kVA Sentinel K Transformer, 3 Ph, AL, 115C, K13, 480D-208Y/120V

Hammond SK3A0225KB3SF
SKU HPS-SK3A0225KB3SF
Hammond's aluminum wound 225kVA 3 phase K-factor Sentinel distribution transformer is rated 480D - 208Y/120V primary/secondary voltage, K13 K rating, 115C temp rise, and a DH5 case style. Explore more distribution transformers at HomElectrical today!
Hammond 225kVA Sentinel K Transformer, 3 Ph, AL, 115C, K13, 480D-208Y/120V

Image may not depict product actual color, inclusions or accessories

Hammond's aluminum wound 225kVA 3 phase K-factor Sentinel distribution transformer is rated 480D - 208Y/120V primary/secondary voltage, K13 K rating, 115C temp rise, and a DH5 case style. Explore more distribution transformers at HomElectrical today!
cUL/UL Listed
CSA US

  • 225kVA, 3 Phase.
  • Primary Voltage: 480 Delta; Secondary Voltage: 208Y/120V.
  • Aluminum Wound with Electrostatic Shield; 115C Temperature Rise; K13 K Rating.
  • K-Factor Transformer - Rated for 600V and below and is specifically designed and tested for applications that use non-linear loads.
  • Floor or Wall/Ceiling mounted.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Standard 10kV BIL rating provides increased reliability and protection against critical equipment failure.
  • All units utilize a uniform 220C insulation system with a 80C, 115C or 150C temperature rise.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short-circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

cUL/UL Listed
CSA US

Hammond SK3A0225KB3SF Description

cUL/UL Listed
CSA US

  • 225kVA, 3 Phase.
  • Primary Voltage: 480 Delta; Secondary Voltage: 208Y/120V.
  • Aluminum Wound with Electrostatic Shield; 115C Temperature Rise; K13 K Rating.
  • K-Factor Transformer - Rated for 600V and below and is specifically designed and tested for applications that use non-linear loads.
  • Floor or Wall/Ceiling mounted.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Standard 10kV BIL rating provides increased reliability and protection against critical equipment failure.
  • All units utilize a uniform 220C insulation system with a 80C, 115C or 150C temperature rise.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short-circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

cUL/UL Listed
CSA US
Free Shipping
$14,381.69Each

Usually Ships 1-2 Months

Product Specifications

Part NumberSK3A0225KB3SF
CertificatecUL/UL Listed, CSA US
Electrical Phase3 Ph
Inner Package1
MaterialAluminum
Warranty10 Yr
Product Dimensions52-in X 37.50-in X 34-in
Weight1,850.00-lb
UPC803423160388

Manufacturer Description

D16 SNTL-K K13 3PH 225KVA 480D-208Y/120V AL 60Hz 115C 3R
Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.
Hammond's aluminum wound 225kVA 3 phase K-factor Sentinel distribution transformer is rated 480D - 208Y/120V primary/secondary voltage, K13 K rating, 115C temp rise, and a DH5 case style. Explore more distribution transformers at HomElectrical today!
Hammond 225kVA Sentinel K Transformer, 3 Ph, AL, 115C, K13, 480D-208Y/120V
Free Shipping
$14,381.69Each

Usually Ships 1-2 Months

Hammond SK3A0225KB3SF Description

cUL/UL Listed
CSA US

  • 225kVA, 3 Phase.
  • Primary Voltage: 480 Delta; Secondary Voltage: 208Y/120V.
  • Aluminum Wound with Electrostatic Shield; 115C Temperature Rise; K13 K Rating.
  • K-Factor Transformer - Rated for 600V and below and is specifically designed and tested for applications that use non-linear loads.
  • Floor or Wall/Ceiling mounted.
  • Standard Type 3R enclosure suitable for indoor or outdoor applications.
  • Standard 10kV BIL rating provides increased reliability and protection against critical equipment failure.
  • All units utilize a uniform 220C insulation system with a 80C, 115C or 150C temperature rise.
  • Manufactured from quality non-aging, cold rolled, silicon steel laminations using state-of-the-art equipment.
  • Cores are precision cut to close tolerances which eliminates burrs and improves performance.
  • Core is coated to prevent the ingress of moisture.
  • Precision wound with copper or aluminum conductors that are electrically balanced to minimize axial forces during short-circuit conditions.
  • Robust interface between core & coils for better short circuit performance.

Product Specifications

Part NumberSK3A0225KB3SF
CertificatecUL/UL Listed, CSA US
Electrical Phase3 Ph
Inner Package1
MaterialAluminum
Warranty10 Yr
Product Dimensions52-in X 37.50-in X 34-in
Weight1,850.00-lb
UPC803423160388

Manufacturer Description

D16 SNTL-K K13 3PH 225KVA 480D-208Y/120V AL 60Hz 115C 3R
Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.

Product Questions & Answers

Customer Reviews

0 out of 5
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Need Assistance?