Rectorseal Metacaulk Cover Guard, Double, Receptacle

Rectorseal 66270
SKU RSL-66270
RectorSeal's Metacaulk cover guard with double receptacle configuration is a fire rated gasket for use with electrical boxes. It mounts on the inside of the cover plate to provide fire protection. Browse more firestop products at HomElectrical.com today!
Rectorseal Metacaulk Cover Guard, Double, Receptacle

Image may not depict product actual color, inclusions or accessories

RectorSeal's Metacaulk cover guard with double receptacle configuration is a fire rated gasket for use with electrical boxes. It mounts on the inside of the cover plate to provide fire protection. Browse more firestop products at HomElectrical.com today!
  • Double; Receptacle.
  • Mounted on inside of cover plate and installed simultaneously - covers the opening and provides necessary fire protection.
  • Easy to install - applied by hand, does not take up volume in the electrical box and a labor-saving replacement for putty pads in normal applications.
  • ASTM E814 (UL 1479).
  • Cost Effective and Great for safe retrofit applications.
  • Reduces sound transmission - STC rating 54.
  • Tested conditions for 1 or 2 hours.
  • Use when Electrical boxes are installed in rated walls facing opposite directions and horizontally separated by less than 24-in.
  • Can also be used as a solution for standard electrical boxes when the 100 square inch rule is violated.
  • Complies to UL required Accelerated Aging and High Humidity Testing.
  • VOC Compliant - CDPH Standard Method.
  • Certifications: UL Certified, FM Approved, Clean Air Gold.

Rectorseal 66270 Description

  • Double; Receptacle.
  • Mounted on inside of cover plate and installed simultaneously - covers the opening and provides necessary fire protection.
  • Easy to install - applied by hand, does not take up volume in the electrical box and a labor-saving replacement for putty pads in normal applications.
  • ASTM E814 (UL 1479).
  • Cost Effective and Great for safe retrofit applications.
  • Reduces sound transmission - STC rating 54.
  • Tested conditions for 1 or 2 hours.
  • Use when Electrical boxes are installed in rated walls facing opposite directions and horizontally separated by less than 24-in.
  • Can also be used as a solution for standard electrical boxes when the 100 square inch rule is violated.
  • Complies to UL required Accelerated Aging and High Humidity Testing.
  • VOC Compliant - CDPH Standard Method.
  • Certifications: UL Certified, FM Approved, Clean Air Gold.
Free Shipping Eligible
$6.08Each
Sold by the Case of 50 for only $304.00
In Stock-

Ships between Dec. 26 - Dec. 30

Product Specifications

Part Number66270
Weight0.05-lb
UPC021449662703

Manufacturer Description

MC COVER GUARD DBL GANG RECPT

Resources & Download

A PDF viewer is required to view this product's information. Download Adobe Acrobat Viewer

Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.
RectorSeal's Metacaulk cover guard with double receptacle configuration is a fire rated gasket for use with electrical boxes. It mounts on the inside of the cover plate to provide fire protection. Browse more firestop products at HomElectrical.com today!
Rectorseal Metacaulk Cover Guard, Double, Receptacle
Free Shipping Eligible
$6.08Each
Sold by the Case of 50 for only $304.00
In Stock-

Ships between Dec. 26 - Dec. 30

Rectorseal 66270 Description

  • Double; Receptacle.
  • Mounted on inside of cover plate and installed simultaneously - covers the opening and provides necessary fire protection.
  • Easy to install - applied by hand, does not take up volume in the electrical box and a labor-saving replacement for putty pads in normal applications.
  • ASTM E814 (UL 1479).
  • Cost Effective and Great for safe retrofit applications.
  • Reduces sound transmission - STC rating 54.
  • Tested conditions for 1 or 2 hours.
  • Use when Electrical boxes are installed in rated walls facing opposite directions and horizontally separated by less than 24-in.
  • Can also be used as a solution for standard electrical boxes when the 100 square inch rule is violated.
  • Complies to UL required Accelerated Aging and High Humidity Testing.
  • VOC Compliant - CDPH Standard Method.
  • Certifications: UL Certified, FM Approved, Clean Air Gold.

Product Specifications

Part Number66270
Weight0.05-lb
UPC021449662703

Manufacturer Description

MC COVER GUARD DBL GANG RECPT

Resources & Download

A PDF viewer is required to view this product's information. Download Adobe Acrobat Viewer

Prop65
Important PROP 65 InformationWarning: This product can expose you to chemicals, which are known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information, go to www.p65warnings.ca.gov. to CA residents.

Product Questions & Answers

Customer Reviews

0 out of 5
5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%
Need Assistance?